350-601 • Practice Test 2 — 10 Questions
Free 350-601 practice test 2 — 10 questions with explanations. No signup required.
A large enterprise is using Cisco UCS Manager to manage a chassis with 8 B-Series blades. The environment uses a combination of Ethernet and Fibre Channel traffic. The UCS fabric interconnect (FI) is configured in end-host mode with two uplinks to the core network. Recently, the engineering team deployed a new service profile for a high-performance computing workload that requires 40Gbps Ethernet per vNIC and 16Gbps Fibre Channel per vHBA. The server has two vNICs and two vHBAs. After deployment, the server's OS shows only 10Gbps connectivity on each vNIC. The engineer checks UCS Manager and sees that the vNIC templates are set to '10 Gbps' and the vHBA templates are set to '16 Gbps' but the actual link speed for vNICs is only 10Gbps. The fabric interconnect ports are configured as 40Gbps uplinks. The engineer has verified that the server adapter supports 40Gbps. What is the most likely cause of the speed mismatch?